The chemistry world model
Systems, their validity, the reference experiments
The whole model and its validation, level by level: verification, the comparison with independent measurements, the virtual laboratory, the pre-registered bench experiments.
Reference experiments
- VCW-001 · potassium chloride precipitated by ethanol PASS
- VCW-002 · sodium bromide precipitated by ethanol PASS
- LARP-001 · Cs3Sb2I9 by ligand-assisted reprecipitation (Mi's synthesis) UNKNOWN
Systems
Potassium chloride in water, precipitated by ethanol (kcl-water-ethanol)
The reference system of the world model: the solubility comes from one published table (Pinho & Macedo 2005). Equilibrium fidelity needs no parameter beyond the table; the kinetic fidelity's parameters are stated with their provenance. The liquid's volume follows a published density table of water + ethanol (Lange 1967) and the salt's apparent molar volume.
Overall: assumed; the weakest module decides: a result is no better than its most assumed parameter.
| Module | Step | Status | Basis |
|---|---|---|---|
| solubility | dissolution and antisolvent addition: how much can stay dissolved | predictive | every value is interpolated between the published table's own points; outside them the model refuses (OutOfValidity) every node reproduced exactly; the equilibrium yield of VCW-001 equals the table's mass balance (tests/test_world_solubility.py, test_world_conservation.py) |
| density | the liquid's volume (concentrations, levels, the pellet's liquid) | predictive | the solvent's density interpolated in a published table (10-30 C; outside it the state falls back to additive volumes and says so); the salt at its apparent molar volume in water, ASSUMED to hold in the mixture (at most 1.5 % of the liquid's volume) the table's pure ends against Tanaka 2001 and the CRC Handbook, its interior against a second compilation; the mixture contracts by about 3 % near equal masses (tests/test_world_density.py) |
| crystallization | nucleation, growth, dissolution (the kinetic fidelity) | assumed | the nucleation exponents are published; the pre-factors are calibrated to published induction times; the growth and dissolution coefficients, the nucleus size, the powder's size distribution and the shape factor are assumed and say so the model's induction times reproduce the published fit at the two calibration points and within 25 % at four others (tests/test_world_kinetics.py); the kinetic run ends at the table's equilibrium |
| mixing | mixing and the antisolvent feed | assumed | one well-mixed compartment with a time-varying volume; the blend time only says when a mix op is homogeneous |
| separation | centrifugation and decanting | assumed | the cut size follows Stokes settling in the stated field; the viscosity, the pellet's porosity and the tube's geometry are assumed RCF and the cut size against the formulas by hand (tests/test_world_separation.py) |
| temperature | heating and cooling | not modelled | the temperature is one constant per protocol; no heat transfer, no evaporation |
| aging | aging (ripening, polymorph transformation) | not modelled | Ostwald ripening and polymorph transformation are absent: a wait only lets nucleation and growth finish |
predictive: an established method with literature or measured parameters, inside their domain · calibrated: an established method with a parameter fitted to a named observation; valid in the fitted domain only · assumed: an established method with a stated, unmeasured parameter: what the model does, not what the bench will do · not modelled: absent from the model; the ledger says so
Sodium bromide in water, precipitated by ethanol (nabr-water-ethanol)
The second system: the same mechanics on another salt from the same published table, equilibrium fidelity only (no kinetics published here). Below 323 K the stable solid in water is the dihydrate NaBr·2H2O: that dataset is left out and pure water is outside the domain, so a protocol starts with some ethanol in the solvent. The solvent's volume follows the water + ethanol density table; NaBr's volume in solution is its crystal volume (ASSUMED).
Overall: assumed; the weakest module decides: a result is no better than its most assumed parameter.
| Module | Step | Status | Basis |
|---|---|---|---|
| solubility | dissolution and antisolvent addition: how much can stay dissolved | predictive | every value is interpolated between the published table's own points; outside them the model refuses (OutOfValidity) every node reproduced exactly; the equilibrium yield of VCW-001 equals the table's mass balance (tests/test_world_solubility.py, test_world_conservation.py) |
| density | the liquid's volume (concentrations, levels, the pellet's liquid) | predictive | the solvent's density interpolated in a published table (10-30 C; outside it the state falls back to additive volumes and says so); the salt at its apparent molar volume in water, ASSUMED to hold in the mixture (at most 1.5 % of the liquid's volume) the table's pure ends against Tanaka 2001 and the CRC Handbook, its interior against a second compilation; the mixture contracts by about 3 % near equal masses (tests/test_world_density.py) |
| crystallization | nucleation, growth, dissolution | not modelled | this system has no kinetics file: only the equilibrium fidelity |
| mixing | mixing and the antisolvent feed | assumed | one well-mixed compartment with a time-varying volume; the blend time only says when a mix op is homogeneous |
| separation | centrifugation and decanting | assumed | the cut size follows Stokes settling in the stated field; the viscosity, the pellet's porosity and the tube's geometry are assumed RCF and the cut size against the formulas by hand (tests/test_world_separation.py) |
| temperature | heating and cooling | not modelled | the temperature is one constant per protocol; no heat transfer, no evaporation |
| aging | aging (ripening, polymorph transformation) | not modelled | Ostwald ripening and polymorph transformation are absent: a wait only lets nucleation and growth finish |
predictive: an established method with literature or measured parameters, inside their domain · calibrated: an established method with a parameter fitted to a named observation; valid in the fitted domain only · assumed: an established method with a stated, unmeasured parameter: what the model does, not what the bench will do · not modelled: absent from the model; the ledger says so
Cs3Sb2I9 by ligand-assisted reprecipitation (CsI + SbI3 in DMF, oleic acid and oleylamine, toluene) (larp-cs3sb2i9)
The research case: the phase that forms (hexagonal 0D dimer, trigonal 2D layered, a mixture, or no Cs3Sb2I9 at all) follows a phase map calibrated to Mi's four observed outcomes by oleylamine volume; outside those amounts the map refuses. Dissolution in DMF and precipitation on toluene addition are taken as complete (ASSUMED); no kinetics, no crystal size.
Overall: assumed; the weakest module decides: a result is no better than its most assumed parameter.
| Module | Step | Status | Basis |
|---|---|---|---|
| stoichiometry | the reagents and the product's formula | predictive | conservation of elements the ledger after every operation |
| dissolution | dissolving the reagents in DMF | assumed | ASSUMED complete at these amounts (0.3 mmol CsI, 0.2 mmol SbI3 in 300 uL) |
| phase selection | the antisolvent addition: what precipitates, which polymorph | calibrated | four parameters fitted to 4 observed classes; outside the stated amounts and 0-700 uL of oleylamine the map refuses the four observed classes are reproduced (by construction); held out one at a time, the interior ones are predicted 0/2: the four labels under-determine the map; the measured spectra are needed before it can be called validated |
| separation | centrifugation and decanting | assumed | the cut size follows Stokes settling in the stated field; the viscosity, the pellet's porosity and the tube's geometry are assumed RCF and the cut size against the formulas by hand (tests/test_world_separation.py) |
| raman | reading the product | not modelled | no measured reference library yet (Mi's spectra pending): the instrument exists, the library does not |
| temperature | heating and cooling | not modelled | the temperature is one constant per protocol; no heat transfer, no evaporation |
| aging | aging (ripening, polymorph transformation) | not modelled | Ostwald ripening and polymorph transformation are absent: a wait only lets nucleation and growth finish |
| crystallization | nucleation, growth, crystal size | not modelled | no kinetics for this system |
predictive: an established method with literature or measured parameters, inside their domain · calibrated: an established method with a parameter fitted to a named observation; valid in the fitted domain only · assumed: an established method with a stated, unmeasured parameter: what the model does, not what the bench will do · not modelled: absent from the model; the ledger says so
How to run one yourself
From the repository: uv run python -m vialbot.chemistry vcw-001 (or vcw-001-kinetic, vcw-002, larp-001), or POST /api/world/run with a protocol (see the API docs). The methods, sources and provenance of every parameter are in the ledger.