Reference experiment · LARP-001
LARP-001 · Cs3Sb2I9 by ligand-assisted reprecipitation (Mi's synthesis) UNKNOWN
0.3 mmol of CsI and 0.2 mmol of SbI3 dissolved in 300 uL of DMF; oleic acid (fixed) and oleylamine (0, 100, 400 or 700 uL); 3 mL of toluene; overnight; 5,000 rpm; the pellet read by Raman. The phase that forms follows a map calibrated to the four observed classes: hexagonal, mixed, trigonal, salts. The reference runs the four observed volumes and states what the map can and cannot say.
Goal: the phase class of the product at each observed oleylamine volume, and the product's amount by stoichiometry
Frozen 2026-10-23 · protocol digest a67019f8cccd753f · record 1c57e6673179fa0d · the record as JSON
1 · The protocol
- add 0.3 mmol of CsI
- add 0.2 mmol of SbI3
- add 300 uL of DMF
- mix 300 s (vortex)
- add 100 uL of oleic_acid
- add 3000 uL of toluene over 10 s
- wait 43200 s
- centrifuge 5000 rpm, 10 min
- decant (keep 20 uL)
- read the raman
- read the balance
2 · The four observed volumes
| oleylamine (µL) | observed (Mi) | the map | layered fraction | free Sb | solid (mg) | CsI in the solid |
|---|---|---|---|---|---|---|
| 0 | hexagonal | hexagonal | 0.00 | 1.00 | 178.4 | 0 % |
| 100 | mixed | mixed | 0.55 | 1.00 | 178.4 | 0 % |
| 400 | trigonal | trigonal | 1.00 | 1.00 | 178.0 | 0 % |
| 700 | salts | salts | 1.00 | 0.20 | 98.5 | 63 % |
The observed classes are the map's calibration points: their agreement is by construction. The amounts are stoichiometric, with complete precipitation assumed.
3 · The checks
| Check | Verdict | What was found | |
|---|---|---|---|
| L0 | Protocol frozen | PASS | The base protocol's digest is a67019f8cccd753f; the frozen one is a67019f8cccd753f; the oleylamine volumes run are [0.0, 100.0, 400.0, 700.0]. sha256 of the checked base protocol (0 uL of oleylamine); frozen on 2026-10-23 |
| L1 | Matter conserved | PASS | Across the four runs, fed = inside + removed to 5.8e-14 mmol, element by element. the runs' ledgers |
| L2 | The observed classes reproduced | PASS | At 0, 100, 400 and 700 uL of oleylamine the map gives 0 uL: hexagonal, 100 uL: mixed, 400 uL: trigonal, 700 uL: salts. These are the calibration points: agreement is by construction, not a test. the phase map against the observations it was fitted to |
| L3 | Interpolation between the observations | UNKNOWN | Refitted with each interior observation left out, the map predicts it 0 time(s) in 2: four class labels under-determine four parameters, so the map is calibrated but not validated; the measured spectra (phase fractions) are needed. leave-one-out refits by scripts/world_calibrate_larp.py |
| L4 | Raman identification | UNKNOWN | No measured reference library yet: the virtual Raman cannot read the product; Mi's spectra are pending. vialbot/instruments/raman.py with a library built from the measured spectra |
| L5 | Amount by stoichiometry | PASS | Without amine the map gives the full stoichiometric product, 0.1 mmol = 178.4 mg (the model's 178.4 mg); with amine the product falls as antimony is complexed (178.0 mg at 400 uL, 98.5 mg of mostly CsI at 700 uL). The yield is ASSUMED complete. 3 CsI + 2 SbI3 = Cs3Sb2I9, with SbI3 the limiting reagent; complete precipitation (ASSUMED) |
| L6 | Refuses what it cannot model | PASS | 3 of 3 probes were refused or answered 'unavailable': ligand_outside_map (OutOfValidity); unknown_op (ContractError); raman_without_library (reading marked unavailable). each probe is the reference protocol with one change the model has no basis for; the only acceptable answer is the one expected of it: a refusal with its reason (OutOfValidity, ContractError), or, for a reading without a library, a reading marked unavailable |
Not evaluated yet: L4 Raman identification against the measured library, L7 Validation at an unobserved oleylamine volume, predicted before the experiment.
4 · What the model is credible for (context of use)
Question: which phase forms and how much, at an oleylamine volume, under the calibrated map.
Intended use: a calibrated map of four observed classes: indicative at the observed volumes, silent elsewhere; none of it is a measurement.
| quantity | value | governed by | sensitivity | decision | why |
|---|---|---|---|---|---|
| phase class of the product (label) | hexagonal / mixed / trigonal / salts at 0 / 100 / 400 / 700 uL | phase selection (calibrated) | undefined | uncertain | calibrated to the four labels it reproduces; the interior is not validated (L3: held-out 0 of 2) and no measured spectrum reads it (L4) evidence: L2, L3 · on the bench: Raman or XRD of the product against measured references |
| mass of product (mg) | 178.4 mg at 0 uL (the stoichiometric maximum) | stoichiometry (predictive), dissolution (assumed) | undefined | uncertain | the stoichiometric ceiling is arithmetic (L5); complete precipitation is assumed, so the actual yield is not predicted evidence: L1, L5 · on the bench: the dried product weighed |
Rule: nothing in this record is supported: a calibrated map with an unvalidated interior and an assumed yield. Framework: ASME V&V 40-2018 (context of use) and the VVUQ view of digital-twin credibility in Shao, Hightower & Schindel, Manufacturing Letters 35 (2023) 24-28.
5 · What it refuses
- ligand_outside_map: the protocol with 900 uL of the ligand, outside the calibrated map's 0-700 uL → refused (OutOfValidity) oleylamine_uL = 900 is outside the calibrated domain [0, 700]: the phase map cannot say what forms there
- unknown_op: a 'heat' operation: no module models heating → refused (ContractError) op 1: must be an object with 'op' one of ('add_solid', 'add_liquid', 'mix', 'add_antisolvent', 'wait', 'centrifuge', 'decant', 'read')
- raman_without_library: a Raman reading of a system without a measured reference library → unavailable (reading marked unavailable) no Raman reference library for the system larp-cs3sb2i9: a reading cannot be produced
each probe is the reference protocol with one change the model has no basis for; the only acceptable answer is the one expected of it: a refusal with its reason (OutOfValidity, ContractError), or, for a reading without a library, a reading marked unavailable.
6 · Predictions at volumes not yet run (pre-registered)
Status: pre-registered predictions at volumes not yet run; no observation yet. Frozen 2026-10-24 with the model a8a57a3e1c3e7de2, now unchanged. Observed so far: 0, 100, 400, 700 µL. Recipe: 0.3 mmol CsI + 0.2 mmol SbI3 in 300 uL DMF; oleic acid (ASSUMED 100 uL) and the oleylamine volume in 3 mL toluene; overnight; 5,000 rpm; the product read by Raman (and XRD if available).
| oleylamine (µL) | amine/Sb | the map says | layered fraction | free Sb | solid (mg) | the alternatives say | agree | label |
|---|---|---|---|---|---|---|---|---|
| 25 | 0.38 | hexagonal | 0.00 | 1.00 | 178.4 | hexagonal | 4/4 | robust |
| 50 | 0.76 | hexagonal | 0.00 | 1.00 | 178.4 | hexagonal | 4/4 | robust |
| 75 | 1.14 | hexagonal | 0.03 | 1.00 | 178.4 | hexagonal, mixed | 3/4 | contested |
| 125 | 1.90 | trigonal | 0.98 | 1.00 | 178.4 | hexagonal, mixed, trigonal | 2/4 | contested |
| 150 | 2.28 | trigonal | 1.00 | 1.00 | 178.4 | hexagonal, trigonal | 3/4 | contested |
| 175 | 2.66 | trigonal | 1.00 | 1.00 | 178.4 | mixed, trigonal | 3/4 | contested |
| 200 | 3.04 | trigonal | 1.00 | 1.00 | 178.4 | mixed, trigonal | 3/4 | contested |
| 250 | 3.80 | trigonal | 1.00 | 1.00 | 178.4 | trigonal | 4/4 | robust |
| 300 | 4.56 | trigonal | 1.00 | 1.00 | 178.4 | trigonal | 4/4 | robust |
| 500 | 7.60 | trigonal | 1.00 | 0.94 | 172.0 | salts, trigonal | 3/4 | contested |
| 550 | 8.36 | trigonal | 1.00 | 0.82 | 160.7 | salts, trigonal | 3/4 | contested |
| 600 | 9.12 | trigonal | 1.00 | 0.62 | 140.3 | salts, trigonal | 3/4 | contested |
Recommended next experiments: to falsify a robust prediction, 25, 50, 250 µL; to discriminate between the maps, 125, 75 µL. run one robust volume (a prediction that can fail) and the most contested one (which selects among the maps); read the product by Raman against the measured library once Mi's spectra are in, or by XRD.
The rules, written before the experiment:
- robust: the prediction holds when the observed class equals the predicted one; one failure falsifies the map as calibrated
- contested: no claim; the observed class picks the surviving maps, and the map is refitted to five labels and re-frozen
- class: the classes as on the slide: hexagonal (0D dimer), mixed, trigonal (2D layered), salts (CsI the majority of the solid by mass)
- freeze: the map and its alternatives are frozen by model_digest; nothing is tuned to the new observation before it is compared
what the calibrated map says at volumes nobody has run, and which of those volumes its own alternatives contest; written before the experiment; a robust row can fail, a contested row selects among the maps. Alternatives: the leave-one-out refits of the map, each consistent with three of the four observed labels.
7 · What this establishes
rests on L1, L5 · arithmetic on the formula; the complete yield is assumed
rests on L2 · calibrated: four parameters to four labels; not a prediction
Not claimed:
- the phase at any oleylamine volume not observed (the map is not validated by interpolation: L3)
- the yield (complete precipitation is assumed)
- the crystal size, the kinetics, the role of the oleic acid and of the addition rate
- any Raman reading (no measured library yet)
- any physical measurement
8 · Calibration, accuracy, precision
- Calibration: the phase map's four parameters, to the four observed classes; reproduces the observations it was fitted to; not validated by interpolation (see L3)
- Accuracy: no measured yield or phase fraction to compare with yet
- Precision: the chemistry is deterministic; the balance's repeatability is that of VCW-001
a calibrated map of four observations, pending the measured spectra; nothing here predicts a condition that was not observed
9 · What the model can say (validity)
Overall: assumed; the weakest module decides: a result is no better than its most assumed parameter.
| Module | Step | Status | Basis |
|---|---|---|---|
| stoichiometry | the reagents and the product's formula | predictive | conservation of elements the ledger after every operation |
| dissolution | dissolving the reagents in DMF | assumed | ASSUMED complete at these amounts (0.3 mmol CsI, 0.2 mmol SbI3 in 300 uL) |
| phase selection | the antisolvent addition: what precipitates, which polymorph | calibrated | four parameters fitted to 4 observed classes; outside the stated amounts and 0-700 uL of oleylamine the map refuses the four observed classes are reproduced (by construction); held out one at a time, the interior ones are predicted 0/2: the four labels under-determine the map; the measured spectra are needed before it can be called validated |
| separation | centrifugation and decanting | assumed | the cut size follows Stokes settling in the stated field; the viscosity, the pellet's porosity and the tube's geometry are assumed RCF and the cut size against the formulas by hand (tests/test_world_separation.py) |
| raman | reading the product | not modelled | no measured reference library yet (Mi's spectra pending): the instrument exists, the library does not |
| temperature | heating and cooling | not modelled | the temperature is one constant per protocol; no heat transfer, no evaporation |
| aging | aging (ripening, polymorph transformation) | not modelled | Ostwald ripening and polymorph transformation are absent: a wait only lets nucleation and growth finish |
| crystallization | nucleation, growth, crystal size | not modelled | no kinetics for this system |
predictive: an established method with literature or measured parameters, inside their domain · calibrated: an established method with a parameter fitted to a named observation; valid in the fitted domain only · assumed: an established method with a stated, unmeasured parameter: what the model does, not what the bench will do · not modelled: absent from the model; the ledger says so