{"id": "world-model", "title": "The chemistry world model: methods, provenance, validity (the ledger)", "heading": "The chemistry world model: methods, provenance, validity", "html": "<h1 id=\"the-chemistry-world-model-methods-provenance-validity\">The chemistry world model: methods, provenance, validity</h1>\n<p>The world model is the chemistry behind the virtual laboratory: reagents with a chemical identity, a vessel whose contents evolve through unit operations, and instruments that read the result. It exists so that a synthesis performed in the 3D room has an outcome computed from stated models, not scripted; and so that a reader can see, for every number, where it comes from and how far it can be trusted. The rule of the room holds: the chemistry calculates, the room displays (ADR-0006).</p>\n<p>This page is the ledger: one row per unit operation, with the method, its source, its parameters' provenance, what checks it against published data, and its status. Statuses, from strongest to weakest:</p>\n<table><thead><tr><th>Status</th><th>Meaning</th></tr></thead><tbody><tr><td><b>predictive</b></td><td>an established method whose parameters are published or measured, used inside their domain</td></tr><tr><td><b>calibrated</b></td><td>an established method with a parameter fitted here to a named observation; valid in the fitted domain only</td></tr><tr><td><b>assumed</b></td><td>an established method with a stated, unmeasured parameter: the result shows what the model does, not what a bench will do</td></tr><tr><td><b>not modelled</b></td><td>the effect is absent; a run that depends on it is not a prediction</td></tr></tbody></table>\n<p>The weakest module a run touches is the status of its result. <code>GET /api/world</code> returns the same verdict per module, and every <code>POST /api/world/run</code> answer carries it.</p>\n<h2 id=\"the-ledger\">The ledger</h2>\n<table><thead><tr><th>Step</th><th>Module</th><th>Method and source</th><th>Parameters (provenance)</th><th>Checked against</th><th>Status</th></tr></thead><tbody><tr><td>Identity and amounts</td><td><code>chemistry/substances.py</code>, <code>examples/world/substances.json</code></td><td>molar mass and element inventory from the formula (IUPAC 2021 abridged atomic weights); densities at 25 \u00b0C from the CRC Handbook / Tanaka 2001</td><td>molar masses: literature; densities: literature; additive volumes: assumed</td><td>CRC molar masses to 0.01 g/mol (<code>tests/test_world_substances.py</code>)</td><td>predictive</td></tr><tr><td>Dissolving, how much can stay dissolved</td><td><code>chemistry/solubility.py</code>, <code>examples/world/solubility_kcl_water_ethanol.json</code></td><td>piecewise-linear interpolation of the published table; no extrapolation (<code>OutOfValidity</code>) \u2014 Pinho &amp; Macedo, J. Chem. Eng. Data 50 (2005) 29, DOI 10.1021/je049922y, as the NIST TRC ThermoML record (<code>scripts/fetch_thermoml.py</code>)</td><td>the table: literature (38 points: KCl in water 298\u2013353 K; in ethanol; in ethanol + water at 298.15, 323.15, 348.15 K); the interpolation's uncertainty: derived from the table's own leave-one-out roughness</td><td>every node reproduced exactly; monotone in composition and temperature; out-of-range refused (<code>tests/test_world_solubility.py</code>)</td><td>predictive within 298.15\u2013348.15 K</td></tr><tr><td>The liquid's volume</td><td><code>chemistry/density.py</code>, <code>examples/world/density_water_ethanol.json</code></td><td>a published density table of water + ethanol by mass fraction at 10, 20, 25, 30 \u00b0C (Lange 1967; the Bureau of Standards' measurements of 1913), linear between its nodes, never extrapolated; the dissolved salt at its apparent molar volume (Masson's form, Millero 1971)</td><td>the table (literature, 101 \u00d7 4 values, U95 1e-4 g/mL assumed); V\u00b0(KCl) 26.85 cm\u00b3/mol and slope 1.87 (literature, water; assumed in the mixture)</td><td>pure ends against Tanaka 2001 and the CRC Handbook; interior against a second compilation; V_\u03c6 against CRC-derived KCl solution densities (within 0.4 cm\u00b3/mol); the 3 % contraction near equal masses</td><td>predictive inside 10\u201330 \u00b0C; assumed outside (additive volumes, stated)</td></tr><tr><td>Mixing</td><td><code>chemistry/mixing.py</code></td><td>a blend time per method; Grenville &amp; Nienow \u03b895 for a stirred vessel (Handbook of Industrial Mixing, 2004, ch. 9); one well-mixed compartment with a time-varying volume</td><td>vial blend times: assumed; stirred correlation: literature</td><td>the flag flips at the blend time</td><td>assumed; the feed zone's micromixing (Ba\u0142dyga &amp; Bourne) is <b>not modelled</b> (R-W04)</td></tr><tr><td>Dissolution, nucleation and growth</td><td><code>chemistry/crystallization.py</code>, <code>examples/world/kinetics_kcl.json</code></td><td>population balance by moments (Randolph &amp; Larson 1988; Hulburt &amp; Katz 1964); classical nucleation theory in two regimes (Mullin 2001 ch. 5; Wang et al., Molecules 28 (2023) 7923); first-order growth (Lopes &amp; Farelo, J. Cryst. Growth 290 (2006) 213, 220); Noyes-Whitney dissolution; integrated by <code>chemistry/ode.py</code> (RK4 with step doubling)</td><td>nucleation exponents B: literature (the slopes of the published induction-time fit); pre-factors A: <b>calibrated</b> to the published induction times at S = 1.04 and 1.10 (<code>scripts/world_calibrate_kcl.py</code>); growth coefficient, dissolution coefficient, nucleus size, shape factor, powder size: assumed</td><td>the model's induction times equal the published fit at the two calibration points and lie within 25 % at the four other published supersaturations; the kinetic run ends at the table's equilibrium to 10\u207b\u2076; a charge below saturation dissolves fully (<code>tests/test_world_kinetics.py</code>)</td><td>assumed (the growth coefficient); calibrated nucleation</td></tr><tr><td>Aging</td><td>\u2014</td><td>a wait lets nucleation and growth finish</td><td>\u2014</td><td>\u2014</td><td>ripening and polymorph transformation <b>not modelled</b> (R-W06)</td></tr><tr><td>Centrifugation and decanting</td><td><code>chemistry/separation.py</code>, <code>instruments/centrifuge.py</code></td><td>RCF = 1.118\u00b710\u207b\u2075 r rpm\u00b2 (the manufacturers' rotor formula); Stokes cut size d_c = \u221a(18 \u03bc h / ((\u03c1_p \u2212 \u03c1_l) a t)) (Svarovsky, Solid-Liquid Separation, 2000, ch. 7); the mass fraction above d_c pellets (lognormal reconstruction of the moments); the pellet keeps liquid at its porosity; suspended crystals leave with the supernatant</td><td>rotor radius, tube geometry, viscosity (1.0 mPa\u00b7s), pellet porosity (0.5): assumed</td><td>RCF and d_c by hand; a weak spin loses fines, the ledger still closes (<code>tests/test_world_separation.py</code>)</td><td>assumed; the mixture's viscosity <b>not modelled</b> (R-W05)</td></tr><tr><td>Weighing</td><td><code>instruments/balance.py</code></td><td>a mass weighed in air against 8,000 kg/m\u00b3 weights (OIML R 111-1), the balance's readability and noise</td><td>readability, noise: assumed (as for the dilution bench)</td><td>the buoyancy factor by hand; noise statistics</td><td>simulated reading</td></tr><tr><td>Temperature</td><td>\u2014</td><td>one constant per protocol</td><td>\u2014</td><td>\u2014</td><td><b>not modelled</b>: no heat transfer, no evaporation (R-W06)</td></tr><tr><td>Conservation</td><td><code>chemistry/state.py</code>, <code>simulate.Ledger</code></td><td>mass and elements balanced after every operation: fed = inside + removed</td><td>\u2014</td><td>\u2264 10\u207b\u2079 mmol on every run; exact fractions for the equilibrium yield (<code>tests/test_world_conservation.py</code>)</td><td>\u2014</td></tr></tbody></table>\n<h2 id=\"the-first-system-vcw-001-potassium-chloride-in-water-precipitated-by-ethanol\">The first system: VCW-001, potassium chloride in water, precipitated by ethanol</h2>\n<p>300 mg of KCl, 1,000 \u00b5L of water, a minute's vortex, 1,500 \u00b5L of ethanol over a minute, an hour's wait, 10 minutes at 4,400 rpm on a 13.7 cm swing-bucket rotor (3,000 \u00d7 g; the protocol said 5,000 rpm on an assumed 12 cm rotor until 2026-10-23, a speed no swing-bucket rotor for 15 mL tubes reaches, and was re-frozen), the supernatant decanted, the pellet weighed. At equilibrium fidelity the only input is the published table: the liquid ends at a water mass fraction of 0.4585, where the table saturates at a KCl mass fraction of 0.0518, so 181.17 mg precipitate and 0.93 mg stay in the 91 \u00b5L of mother liquor the pellet holds. At kinetic fidelity the course is different and the end the same: the powder dissolves within 30 s, supersaturation builds to 2.3 through the feed (nucleation is slow at the calibrated rates: half a milligram by the end of the minute), the burst comes in the first minutes of the wait, the liquid settles at S = 1.0000 after 15 minutes, with crystals of about 430 \u00b5m, and the same 181.17 mg are pelleted. Run it: <code>uv run python -m vialbot.chemistry vcw-001</code> or <code>vcw-001-kinetic</code>.</p>\n<p>What this run establishes: the equilibrium yield, within the table's expanded uncertainty (predictive). What it does not: the time course and the crystal size, which rest on an assumed growth coefficient (assumed); the pellet's liquid content (assumed porosity). The verdict of the run says so.</p>\n<h2 id=\"the-second-system-vcw-002-sodium-bromide-in-water-precipitated-by-ethanol\">The second system: VCW-002, sodium bromide in water, precipitated by ethanol</h2>\n<p>The same mechanics on another salt of the same published table, to check that nothing in the model is particular to KCl. Sodium bromide brings two things the first system lacked. Below 323 K its stable solid in pure water is the dihydrate NaBr\u00b72H\u2082O, so the table's pure-water dataset at 25 \u00b0C belongs to another crystal: the model's crystal filter leaves it out, the domain at 298.15 K stops at a water mass fraction of 0.9, and a protocol that starts in pure water is refused rather than guessed (the reference therefore puts 150 \u00b5L of ethanol in before the water). And NaBr is so soluble that the last of the antisolvent redissolves a little: the solvent mass grows faster than the saturation falls, so the solid passes through a maximum during the feed. 1,000 mg of NaBr end as 172.65 mg of pellet with 54 \u00b5L of mother liquor; the gates pass at equilibrium fidelity, and the record says there are no kinetics for this system.</p>\n<p>VCW-002 also shows why VCW-001 is the better reference: the table's expanded uncertainty, propagated to the yield by the mass balance (dm/dw* = m_solvent/(1 \u2212 w*)\u00b2), is 3.4 % for KCl and 17 % for NaBr, whose high solubility amplifies it.</p>\n<h2 id=\"calibration-accuracy-precision\">Calibration, accuracy, precision</h2>\n<p>Every reference record carries a <code>metrology</code> block, in the metrological sense and about the simulation:</p>\n<ul><li><b>calibration</b>: which parameters were fitted to what. For KCl the two nucleation pre-factors, to published induction times at S = 1.04 and 1.10; the model is exact there and within 25 % at the four other published supersaturations, which were not used. For NaBr nothing is calibrated: the equilibrium fidelity uses the table alone.</li><li><b>accuracy</b>: the yield's expanded uncertainty from the table (above), and the table against an independent source. The NIST record and a secondary compilation (the 20 and 30 \u00b0C values commonly reproduced from the CRC Handbook) differ by +0.64 % for KCl in water at 25 \u00b0C; the compilation's NaBr row cannot be matched to a crystal, so NaBr is not cross-checked, and the record says so.</li><li><b>precision</b>: thirty seeds of the same protocol give the same chemistry and a balance reading whose standard deviation (0.056 mg) matches the instrument's stated noise and readability (0.058 mg expected).</li></ul>\n<p>These numbers say how well the model agrees with the published numbers it rests on and how repeatable its virtual instrument is; they say nothing about how a bench run would come out.</p>\n<h2 id=\"the-research-case-larp-001-cs-sb-i-by-ligand-assisted-reprecipitation\">The research case: LARP-001, Cs\u2083Sb\u2082I\u2089 by ligand-assisted reprecipitation</h2>\n<p>Mi's synthesis: 0.3 mmol of CsI and 0.2 mmol of SbI\u2083 dissolved in 300 \u00b5L of DMF; oleic acid (fixed) and oleylamine (varied) in the antisolvent; 3 mL of toluene; overnight; 5,000 rpm; the pellet read by Raman. Her four outcomes by the oleylamine volume, as photographed from the slide on 2026-10-22: 0 \u00b5L the hexagonal 0D dimer phase (P6\u2083/mmc), 100 \u00b5L a mixture, 400 \u00b5L the trigonal 2D layered phase (P-3m1), 700 \u00b5L \"salts\" (no Cs\u2083Sb\u2082I\u2089).</p>\n<p>No published solubility or kinetics exist for this mixture, so the module that decides the product (<code>chemistry/larp.py</code>) is a <b>calibrated phase map</b>, and the record says so at every turn. Its mechanisms are stated: stoichiometry (3 CsI + 2 SbI\u2083 = Cs\u2083Sb\u2082I\u2089, elements balanced); complete precipitation on toluene addition (assumed); complexation of antimony by the amine as a Hill function of the amine-to-antimony molar ratio (calibrated: at a high ratio little Cs\u2083Sb\u2082I\u2089 can form and the caesium iodide left precipitates, the \"salts\"); the layered phase's share as a logistic in the same ratio (calibrated). Four parameters are fitted to the four classes by <code>scripts/world_calibrate_larp.py</code>, which searches for the map that reproduces every class with the widest margin and the least salt in the outcomes the slide names as Cs\u2083Sb\u2082I\u2089. Refitted with each interior observation left out, the map predicts neither of them (100 \u00b5L comes out hexagonal, 400 \u00b5L salts): four labels under-determine four parameters. The reference record (<code>GET /api/world/reference/larp-001</code>) therefore reads <b>UNKNOWN</b>: the observed classes are reproduced by construction (L2), interpolation is not validated (L3), the Raman reading waits for a measured library (L4); only the stoichiometric amount (L5, 178.4 mg at most) and the conservation (L1) are established. Outside the stated amounts and 0\u2013700 \u00b5L of oleylamine the map refuses.</p>\n<p>What will change it: Mi's spectra files turn the four classes into phase fractions (<code>scripts/world_raman_library.py</code> builds the Raman library; the identification by non-negative least squares gives the fractions with their uncertainty), which constrain the map's transition far better than labels; a measurement at an unobserved volume (say 250 \u00b5L, which the current map calls trigonal) is the first real test of prediction.</p>\n<table><thead><tr><th>Step</th><th>Module</th><th>Method and source</th><th>Parameters (provenance)</th><th>Checked against</th><th>Status</th></tr></thead><tbody><tr><td>Phase selection (LARP)</td><td><code>chemistry/larp.py</code>, <code>examples/world/larp001_phase_map.json</code></td><td>stoichiometry; complete precipitation; Hill complexation of Sb by the amine; logistic polymorph fraction in the amine-to-Sb ratio (Saparov 2015 for the polymorphs; Adv. Sci. 2025 for amine-mediated 0D/2D interconversion in films)</td><td>r_K, n, r50, w: calibrated to four classes from the slide; yield fraction: assumed</td><td>the four classes (by construction); leave-one-out: 0/2 interior</td><td>calibrated, not validated</td></tr><tr><td>Raman reading</td><td><code>instruments/raman.py</code></td><td>linear mixing of unit-area reference spectra, Lorentzian broadening, polynomial baseline, shot noise; identification by non-negative least squares (support enumeration) with \u03c3\u00b2(X\u1d40X)\u207b\u00b9 uncertainties</td><td>resolution, signal, baseline: assumed; the library: pending (measured)</td><td>synthetic mixtures recovered within their uncertainty (<code>tests/test_world_raman.py</code>)</td><td>instrument ready; library pending</td></tr></tbody></table>\n<h2 id=\"credibility-verification-uncertainty-validity-validation-vvuq\">Credibility: verification, uncertainty, validity, validation (VVUQ)</h2>\n<p>A reference record says what it is credible for, in the sense of ASME V&amp;V 40 (a context of use; verification, validation and applicability as the credibility factors) and of the VVUQ view NIST applies to digital twins (Shao, Hightower &amp; Schindel 2023). Four pieces, each computed from the engine with its acceptance rule stated beforehand (<code>web/worldcred.py</code>), shown on <code>/world/reference/&lt;id&gt;</code>:</p>\n<table><thead><tr><th>Piece</th><th>Question</th><th>Method</th><th>Acceptance</th><th>VCW-001 (2026-10-23)</th></tr></thead><tbody><tr><td>Verification (W6)</td><td>is the mathematical model solved correctly?</td><td>the kinetic protocol integrated again with tolerances ten and a hundred times tighter; eight quantities of interest compared; the conservation error against the balance's readability</td><td>every quantity moves by less than 1 %; conservation far below the readability</td><td>6 \u00d7 10\u207b\u2078 relative at most (the mean size); conservation 11 orders of magnitude below 0.1 mg</td></tr><tr><td>Uncertainty (sensitivity)</td><td>which outputs rest on assumed parameters?</td><td>one parameter at a time across a stated range: growth and dissolution coefficients \u00d71/3 and \u00d73, nucleus size a decade either way, powder size and width, shape factor, pellet porosity 0.4\u20130.6, viscosity 1.0\u20132.5 mPa s, +1 K</td><td>robust \u2264 5 %, sensitive &gt; 20 %, moderate between</td><td>yield, concentration and dry mass robust (\u2264 2 %, driven by +1 K); wet pellet moderate (16 %, porosity); mean size sensitive (28 %, growth coefficient); onset and peak supersaturation sensitive (a dissolution coefficient three times slower leaves the charge undissolved when the feed starts)</td></tr><tr><td>Validity (W7, L6)</td><td>does it refuse what it cannot model?</td><td>probes: a temperature below and above the table, water alone where the table has no point, an operation without a module (\"heat\"), a Raman reading without a library, a ligand volume outside the calibrated map</td><td>every probe refused with its reason, or a reading marked unavailable; never a number</td><td>4 of 4 (VCW-001), 5 of 5 (VCW-002), 3 of 3 (LARP-001); the route answers 422 OUT_OF_VALIDITY</td></tr><tr><td>Validation (W8)</td><td>does it agree with bench runs it has not seen?</td><td>the pre-registered campaign VCW-001-V (next section)</td><td>written before the experiments</td><td>not run: no physical experiment yet</td></tr></tbody></table>\n<p>The context of use turns these into a decision per quantity: <b>supported</b> when every governing module is predictive or calibrated inside its domain and the quantity is robust to the assumed parameters; <b>unsupported</b> when a module it needs is not modelled or the fidelity does not give it; <b>uncertain</b> otherwise, with the driver named. For VCW-001 the yield before separation and the concentration left in the liquid are supported; the dry mass of the pellet is uncertain because the separation module is assumed (it moves by 1 % only); the wet pellet, the onset, the peak supersaturation, the mean crystal size and the fraction pelleted are uncertain. For VCW-002 the same two are supported and the kinetic quantities are unsupported (no kinetics). For LARP-001 nothing is supported.</p>\n<p>A run with overridden parameters (a sensitivity or convergence study) carries an <code>overrides</code> block, a different digest and a chemistry note saying the parameters are not the system's: it cannot be mistaken for the reference run. The dry mass of a pellet (the solid plus the solute dissolved in the liquid the pellet kept) is a derived quantity of every state: it is what a drying step leaves, the number a dried bench pellet is compared with; a wet-pellet weighing is not.</p>\n<h2 id=\"validation-against-independent-measurements\">Validation against independent measurements</h2>\n<p>The supported predictions rest on the solubility table (Pinho &amp; Macedo 2005), the concentrations also on the density model. Both are compared with laboratories the model was not built from: <code>vialbot/examples/validation/kcl_water_ethanol_independent.json</code>, written by <code>scripts/fetch_independent_solubility.py</code> from the sources (kept outside the repository, their sha256 recorded; the PDF table's values are checked against its extracted text). The file lies outside the world model's digest: no model reads it, and the pre-registrations stay frozen. <code>web/worldvalid.py</code> scores every point: E = model \u2212 measurement (ASME V&amp;V 20), zeta = E over the two standard uncertainties combined (ISO 13528), |zeta| \u2264 2 agrees, up to 3 questionable, beyond disagrees; a point outside the domain would be refused. <code>GET /api/world/validation</code> serves the comparison and <code>/world/overview</code> shows it with the rest of the evidence, level by level.</p>\n<table><thead><tr><th>Data</th><th>What</th><th>Points</th><th>Result (2026-10-23)</th></tr></thead><tbody><tr><td>Chiavone-Filho &amp; Rasmussen, J. Chem. Eng. Data 38 (1993) 367, Table II (doi 10.1021/je00011a009)</td><td>KCl solubility at 298, 323, 348 K, 0\u2013100 % water; U95 taken as the stated reproducibility, 0.1 mass %</td><td>18</td><td>17 agree, 1 questionable (348 K, 56 % water: +0.9 %, zeta 2.2). At 55.8 % water and 298 K, where the case lives: +1.2 % (zeta 0.7), a yield shift of +2.0 \u00b1 2.1 mg against the prediction's \u00b1 5.6 mg</td></tr><tr><td>Farelo, Lopes &amp; Ferra, J. Chem. Eng. Data 49 (2004) 1782 (doi 10.1021/je049782s), NIST ThermoML</td><td>KCl molality at 298\u2013323 K, 80 and 90 % water; the record's composition label read as a mass fraction (as a mole fraction every point disagrees with every source by 27\u201375 %)</td><td>8</td><td>7 agree, within 0.5 %; 1 disagrees: 323 K, 80 % water, +2.3 % (zeta 12) where the table states \u00b1 0.3 %</td></tr><tr><td>Galleguillos, Taboada, Graber &amp; Bolado, J. Chem. Eng. Data 48 (2003) 405 (doi 10.1021/je020173z), NIST ThermoML</td><td>KCl solubility at 298 and 313 K, 10\u2013100 % water; NIST's U95 \u00b1 2 mass %</td><td>20</td><td>all agree because none can disagree: the points scatter by 10\u201320 % and test nothing at the precision a decision needs</td></tr><tr><td>the same paper, densities</td><td>the saturated solutions' density, the model given their measured composition</td><td>20</td><td>at 298 K 8 of 10 agree, all within 1.2 % (median 0.4 %; within 0.4 % where the case lives); the two that do not (63 and 71 % water, much salt) point at the salt's volume taken from water; the 10 at 313 K lie outside the density table and are not compared</td></tr><tr><td>Wang et al. 2023, the calibration's own source</td><td>induction times in water</td><td>6</td><td>fitted at 2; the other 4 within 22 %: an internal check, not an independent laboratory</td></tr></tbody></table>\n<p>What it establishes: where the case lives (38\u201357 % water at 25 \u00b0C) the one sharp independent point agrees with the table inside the prediction's own uncertainty; in water-rich solvent the sharp datasets agree within 0.5 % but for one point; the density model holds within 1.2 % at 25 \u00b0C. What it does not: the table's stated uncertainty is one laboratory's and narrower than the spread between laboratories in water-rich solvent; between 20 and 55 % water no precise independent point exists, so the middle of the case's range rests on the table alone until the bench campaign measures it. The crystallisation kinetics and the LARP phase map have no independent data.</p>\n<h2 id=\"validation-against-the-bench-the-pre-registered-campaign-vcw-001-v\">Validation against the bench: the pre-registered campaign VCW-001-V</h2>\n<p><code>docs/validation/vcw-001-v-campaign.md</code> is the laboratory protocol; <code>vialbot/examples/world/vcw001_v_preregistration.json</code> holds the model's predictions with their intervals for 18 experiments (ethanol 1,000 / 1,500 / 2,000 \u00b5L, fed fast or slow, three independent runs each), the digest of the frozen model, what to measure and the acceptance rules, all written on 2026-10-23 before any experiment. The supported predictions are the crystallised mass (146.4 \u00b1 5.6, 181.2 \u00b1 6.1 and 206.0 \u00b1 3.7 mg) and the concentration left in the liquid (1,035 \u00b1 35, 648 \u00b1 31 and 429 \u00b1 16 mM), the same at both feed rates: that rate independence is a falsifiable claim of the one-compartment mixing model (R-W04). The onset, the size and the wet pellet are recorded to calibrate the next frozen model, never counted as validation. <code>scripts/world_validate.py</code> judges a measured CSV by those rules and refuses to compare a model that changed since the freeze unless told to, saying so in the report's first line. Nothing has been measured yet: the reference's gate W8 stays \"to come\" until it has.</p>\n<h3 id=\"predictions-at-unobserved-oleylamine-volumes-larp-001-p-pre-registered\">Predictions at unobserved oleylamine volumes: LARP-001-P (pre-registered)</h3>\n<p>The map's four parameters were fitted to four labels, and its leave-one-out refits are alternative maps equally consistent with three of them. <code>scripts/world_preregister_larp.py</code> writes, before any such experiment, what the main map predicts at twelve volumes nobody has run (25 to 600 \u00b5L) and whether every alternative agrees (<code>larp001_p_preregistration.json</code>, frozen with the model's digest). On 2026-10-23: 25, 50, 250 and 300 \u00b5L are robust predictions (hexagonal, hexagonal, trigonal, trigonal: one wrong observation falsifies the map as calibrated); 75 to 200 \u00b5L and 500 to 600 \u00b5L are contested (the alternatives disagree on where the mixed-to-trigonal and the trigonal-to-salts transitions fall). The recommended next experiments are one robust volume (250 \u00b5L) and the most contested one (125 \u00b5L), read by Raman against the measured library once Mi's spectra are in, or by XRD. Gate L7 stays \"to come\" until an observation exists.</p>\n<h2 id=\"the-reference-case-vcw-001-in-a-realistic-virtual-laboratory\">The reference case VCW-001 in a realistic virtual laboratory</h2>\n<p><code>/world/case/vcw-001</code> (record: <code>GET /api/reference/vcw-001</code>) makes VCW-001 a reference case in the full sense of DUV-001: a goal and a decision rule frozen first, a model that designs the recipe, a laboratory that is not the model, instruments that only read it, a decision that names the cause of a miss and corrects the belief, and an evidence package anyone can verify. Design: <code>VialBot_progress/PLAN_VCW_reference_case.md</code> (with the literature sweep and the review it went through).</p>\n<p><b>The goal</b> (frozen, digest <code>35901e3371c97d1b</code>): 180.0 mg of dry KCl crystals from 300 mg of KCl in 1,000 \u00b5L of water, within 6 % at P = 0.95, at 25.5 \u00b0C (0.5 \u00b0C above the table's lowest isotherm, so that the thermoblock's \u00b10.5 \u00b0C keeps the solution inside the model's domain). Six per cent is the smallest tolerance the published table's own uncertainty lets the model promise: the table is 53-76 % of the prediction's variance.</p>\n<p><b>The laboratory</b> (<code>web/kcllab.py</code>, <code>vialbot/instruments/labkit.py</code>): an analytical balance (repeatability 0.08 mg, linearity, buoyancy to conventional mass, static on plastic tubes, a warm tube reading light), ISO 8655 pipettes with ethanol's volatile shortfall (forward or reverse technique), a syringe pump (accuracy, slack unless primed), a thermoblock (\u00b10.5 \u00b0C), an Eppendorf 5702 R-class centrifuge (A-4-38 rotor: 4,400 rpm, 13.7 cm; it stops on 'Inb' without a counterweight and on 'SPEED' above its limit), a drying oven (it refuses vessels still wet with ethanol and temperatures that deform polypropylene), a desiccator, a densitometer (DMA 35-class) and a class AA thermometer. Every instrument's specification has its source; each unit on the bench has hidden characteristics drawn inside it.</p>\n<p><b>The hidden laboratory</b> is not the model: its KCl has moisture and impurities, its ethanol a little water, its solubility differs from the table within the spread of independent datasets and bends between the table's points (logarithmic, not straight), its pellets keep a film and lose a few crystals on decanting, its residues dry over hours. Two scenarios: <code>nominal</code>, and the hidden <code>wrong-ethanol</code> (the bottle labelled 'Ethanol absolute' holds Ph. Eur. 96 % ethanol). Nothing hidden leaves the server (a leak test searches every answer for the hidden values).</p>\n<p><b>The procedure</b> follows practice: the block checked with the thermometer first; every addition weighed (a gravimetric preparation); the ethanol evaporated in the fume hood before the oven; drying to constant mass (two weighings within 0.5 mg); the yield corrected for the KCl the pellet's mother liquor carried, from the decanted supernatant's measured mass fraction (which is itself a measurement of the solubility at the end composition).</p>\n<p><b>Results on the reference seed (4242):</b> nominal: tube 1, 184.9 mg (U 0.5 mg), accepted; zeta +1.0 against the model's prediction for the tube as made. Wrong ethanol: tube 1, 161.8 mg, rejected; zeta \u22124.2 (yield) and +5.1 (supernatant): the solvent was wetter or the block warmer than believed; the densitometer reads 0.8095 g/cm\u00b3 where absolute ethanol gives 0.7878 (zeta +27): the bottle holds 7.6 \u00b1 0.3 % water (the hidden value was 7.1 %); the belief is standardised and tube 2 takes 2,170 \u00b5L: 181.9 mg, accepted. Both scenarios' evidence packages verify (G6 PASS, VALID).</p>\n<p><b>In the 3D lab</b> (<code>/lab</code>, missions \"Reference case VCW-001\" and \"VCW-001: the bottle that is not what it says\"): a crystallisation bench along the right wall (reagents with the 'Ethanol absolute' bottle, P1000 and P5000, a tube rack, vortex, thermoblock with the reference thermometer, syringe pump, a swing-bucket centrifuge), a drying bench in the back-right corner (oven, desiccator, densitometer), a hot plate in the fume hood, and the analytical balance shared with the dye experiment. Each station's panel sends one action of the notebook to <code>POST /api/world/bench</code>; the displays and the tube show the server's answer; the strip at the top follows the procedure (prepare, make, crystallise, separate, dry, decide) with \"Take me there\" and \"Do it\"; \"Watch the demo\" walks the room through the procedure with each step's reason. The mission card shows the server's gates; the decision waits for the visitor's own answer. <code>web/static/labkcl.js</code>; tested by <code>scripts/ui_smoke.mjs</code> (jsdom) and <code>scripts/e2e_kcl.mjs</code> (real Chromium).</p>\n<p><b>What it does not claim:</b> crystal size or onset (the model's size is likely too large); that the hidden laboratory is a real one; the table validated by a virtual laboratory; any physical measurement. Every ASSUMED magnitude is listed in the record with what would measure it.</p>\n<h2 id=\"how-a-system-is-added\">How a system is added</h2>\n<p>A substances entry per reagent (formula, density, source); a solubility table from a cited source with its own fetch script; a kinetics file whose every parameter names its provenance, written by a calibration script that states what was fitted to what; tests that reproduce the sources' numbers. A hidden scenario (a reagent not what its label says) is declared in the system, as the dilution bench does, and its truth never reaches the page.</p>\n<h2 id=\"what-is-not-established\">What is not established</h2>\n<p>Nothing physical was measured in this project. The liquid's volume rests on a published density table of water + ethanol (10\u201330 \u00b0C) and on the salt's apparent molar volume in water, assumed to hold in the mixture; outside the table's temperatures the volumes are additive and the state says so. The solubility table is someone else's measurement, reproduced and checked against three other laboratories: its stated uncertainty is narrower than their spread in water-rich solvent, and between 20 and 55 % water no precise independent point exists. The nucleation pre-factors are fitted to someone else's induction times, measured in water and assumed to hold in the mixture; the growth and dissolution coefficients, the powder, the viscosity, the pellet's porosity and the tube's geometry are stated choices. The size-independent moment method dissolves the last per cent of a charge at once when the mean size reaches zero. The vessel is one well-mixed compartment: the local supersaturation where the antisolvent enters, which decides much in real precipitations, is not modelled. Everything here is simulated; its results are virtually qualified, never validated.</p>\n<h2 id=\"references\">References</h2>\n<ul><li>Pinho, S. P.; Macedo, E. A. Solubility of NaCl, NaBr, and KCl in water, methanol, ethanol, and their mixed solvents. J. Chem. Eng. Data 2005, 50, 29\u201332. DOI 10.1021/je049922y. NIST TRC ThermoML record.</li><li>Independent data (validation only, never read by the model): Chiavone-Filho, O.; Rasmussen, P. Solubilities of salts in mixed solvents. J. Chem. Eng. Data 1993, 38, 367\u2013369, DOI 10.1021/je00011a009. Farelo, F.; Lopes, A. M. C.; Ferra, M. I. Solubilities of sodium chloride and potassium chloride in water + ethanol mixtures from (298 to 323) K. J. Chem. Eng. Data 2004, 49, 1782\u20131788, DOI 10.1021/je049782s. Galleguillos, H. R.; Taboada, M. E.; Graber, T. A.; Bolado, S. Compositions, densities, and refractive indices of potassium chloride + ethanol + water and sodium chloride + ethanol + water solutions at (298.15 and 313.15) K. J. Chem. Eng. Data 2003, 48, 405\u2013410, DOI 10.1021/je020173z.</li><li>ASME V&amp;V 20-2009, Standard for verification and validation in computational fluid dynamics and heat transfer (the comparison error E = S \u2212 D). ISO 13528:2022, Statistical methods for use in proficiency testing by interlaboratory comparison (the zeta score).</li><li>Wang, G.; Bian, X.; Shang, Z.; Dong, W.; Zhang, Y.; Wu, S. Effects of different flotation agents on the nucleation and growth of potassium chloride. Molecules 2023, 28, 7923. DOI 10.3390/molecules28237923.</li><li>Lopes, A.; Farelo, F. Growth kinetics of potassium chloride I: pure aqueous solutions; II: water\u2013ethanol systems. J. Cryst. Growth 2006, 290, 213\u2013219 and 220\u2013224.</li><li>Randolph, A. D.; Larson, M. A. Theory of Particulate Processes, 2nd ed.; Academic Press, 1988. Hulburt, H. M.; Katz, S. Chem. Eng. Sci. 1964, 19, 555.</li><li>Mullin, J. W. Crystallization, 4th ed.; Butterworth-Heinemann, 2001.</li><li>Svarovsky, L. Solid-Liquid Separation, 4th ed.; Butterworth-Heinemann, 2000.</li><li>Grenville, R. K.; Nienow, A. W. Blending of miscible liquids. In Handbook of Industrial Mixing; Wiley, 2004.</li><li>Ba\u0142dyga, J.; Bourne, J. R. Turbulent Mixing and Chemical Reactions; Wiley, 1999.</li><li>OIML R 111-1 (2004), Weights of classes E1 to M3; ISO 8655-6 (gravimetric reference method).</li><li>IUPAC CIAAW, abridged standard atomic weights (2021). CRC Handbook of Chemistry and Physics (densities).</li><li>Lange, N. A. Lange's Handbook of Chemistry, 10th ed. (ed. J. A. Dean); McGraw-Hill, 1967: density of aqueous ethanol by mass fraction at 10, 20, 25 and 30 \u00b0C (as transcribed on Wikipedia's \"Ethanol (data page)\", fetched 2026-10-23, sha256 recorded in the data file). Primary measurements: Osborne, N. S.; McKelvy, E. C.; Bearce, H. W. Bull. Bur. Stand. 1913, 9, 327\u2013474. Tanaka, M. et al. Metrologia 2001, 38, 301 (water).</li><li>Millero, F. J. The molal volumes of electrolytes. Chem. Rev. 1971, 71, 147\u2013176 (conventional partial molal volumes of K\u207a and Cl\u207b at 25 \u00b0C; the Debye\u2013H\u00fcckel limiting slope), checked here against CRC-derived densities of aqueous KCl.</li><li>ASME V&amp;V 40-2018, Assessing credibility of computational modeling through verification and validation: application to medical devices (the context-of-use and credibility-factor framework, used here outside its original field).</li><li>Shao, G.; Hightower, J.; Schindel, W. Credibility consideration for digital twins in manufacturing. Manufacturing Letters 2023, 35, 24\u201328 (VVUQ for digital twins).</li><li>Wright, L.; Davidson, S. How to tell the difference between a model and a digital twin. Adv. Model. Simul. Eng. Sci. 2020, 7, 12 (a model becomes a twin only with evolving data and a way to update it: this world model is a model).</li><li>Darvish, K. et al. MATTERIX: toward a digital twin for robotics-assisted chemistry laboratory automation. Nat. Comput. Sci. 2026, 6, 67\u201382. DOI 10.1038/s43588-025-00924-4 (modular device behaviour and sim-to-real testing).</li><li>Barhate, Y.; Kilari, H.; Wu, W.-L.; Nagy, Z. K. Population balance model enabled digital design and uncertainty analysis framework for continuous crystallization of pharmaceuticals. Chem. Eng. Sci. 2024, 287, 119688.</li><li>Nai, D.; Li, H.; Grover, M.; Medford, A. Modeling batch crystallization under uncertainty using physics-informed machine learning. arXiv:2602.07184 (2026) (robustness of population-balance predictions to an imperfect solubility model).</li></ul>", "path": "docs/world-model.md"}